Dental X-ray Sensors: DEXIS, Schick, Carestream, Vatech
X-ray sensor size, cable, and software lock-in, and how DEXIS, Dentsply Sirona, Carestream, and Vatech differ from phosphor plates.
Reviewed by Dr. Sean Myran, DMDDoctor of Dental Medicine, University of Pennsylvania
How we rank explains how these product lists are ordered.
A digital X-ray sensor is the rigid plate on a cable that captures a bitewing or periapical in a few seconds. It is not a panoramic unit, not a CBCT, and not an intraoral camera. Phosphor plates are the other digital path: a flexible plate goes in the mouth, then a reader scans it. Plates and sensors solve the same radiographs with different workflow. This guide is about sensors. The exposure still comes from an intraoral x-ray unit.
How to choose a sensor

- Sizes. Size 2 is the adult bitewing and posterior periapical. Size 1 is easier on smaller mouths. Size 0 is for children. Most offices need at least one size 2 per working room, plus a smaller sensor if they see kids. One sensor shared across the hall does not survive a busy hygiene day.
- Cable and durability. The cable and the housing corners are what fail, usually from bites and drops, not from the chip. Ask what the warranty actually covers and what a replacement sensor costs in year three. Rounded corners and a thin body matter more to patients than a marketing line about resolution.
- Software. Some sensors open in the vendor’s imaging program only. Some bridge into the practice-management chart you already use. A sensor that forces a second image library will be fought by the team. Test a capture on your current software before you sign.
- Holders. The sensor is useless without a positioning system that fits that brand’s thickness. Budget the holders with the sensor. Holders and barriers are covered on the imaging hub.
- Sensor or plate. Sensors are faster and have a higher replacement cost when one is damaged. Plates are cheaper to lose and slower, because each exposure is scanned. Do not buy both systems unless you have a reason, such as a plate for pediatrics and sensors for adults.
How common sensor lines differ

| Brand | Known for | Best fit | Watch for |
|---|---|---|---|
| DEXIS | Titanium and related sensors in DEXIS imaging | Offices already storing radiographs in DEXIS | A DEXIS sensor is a weak fit if images must live in another suite |
| Dentsply Sirona | Schick 33 and Xios XG Supreme, both still on the current sensor pages | Practices on Sidexis 4 | The older XIOS and XIOS Plus systems are on the discontinued list. USB 2 Schick interfaces are discontinued, with support stated through July 2027 |
| Carestream Dental | RVG and CS 6200 sensors in CS Imaging | Offices on Carestream software or a CS panoramic | Match the sensor to the software, not just the generator |
| Vatech | EzSensor, often quoted below the premium U.S. brands | Offices comparing acquisition cost against DEXIS or Schick | Test the software bridge. The price advantage disappears if the team will not use it |
DEXIS
DEXIS sensors are built to live in DEXIS imaging, next to DEXIS cameras and, in many offices, a DEXIS panoramic. That is the right buy when the chart already opens those images. It is the wrong buy when you would be starting a second radiograph database to accommodate one brand of sensor.
Dentsply Sirona
Schick 33 and Xios XG Supreme are the sensors on Dentsply Sirona’s current pages. Both product pages list a 15 μm pixel and a theoretical resolution of 33 lp/mm, in three sizes. The August 2026 Xios XG Supreme instructions say 33.3 lp/mm and give a size 2 housing of 30.7 × 43.7 × 8.2 mm, which does not match the 31.2 × 43 × 7.5 mm housing on the product page. Use the instructions that ship with the sensor. The discontinued-products list includes the older XIOS Sensor System and XIOS Plus, not these two current names. Schick’s support page says the USB 2.0 interface is discontinued and remains in support through July 2027. USB 3 is the interface on the current Schick 33 and Xios XG Supreme pages. Neither page lists a price.
Carestream
RVG is the name Carestream’s sensor line carried for years. The CS 6200 is the current compact sensor in that family. Both expect CS Imaging. If the panoramic unit is a CS 8100, keeping the sensor in the same software is the practical reason to choose it.
Vatech
EzSensor is the sensor Vatech offers against the higher-priced U.S. lines. The useful comparison is not the spec-sheet line pairs. It is whether a captured image files into the software your assistants already have open, and what a broken size 2 costs to replace.
Published specifications
Pixel size and active area are included only when the manufacturer published them for that sensor. A blank cell was not on the page checked for this update. Resolution claims are not a reason to skip a test exposure in your own software.
| Sensor | Pixel size | Size | Connection |
|---|---|---|---|
| DEXIS Ti2 | 19.5 µm. DEXIS also lists a theoretical resolution of 25.6 lp/mm and a visible resolution of 20+ lp/mm | 39.86 × 29.76 mm. Image 1692 × 1324 pixels | USB 2.0 / USB 3.0. Cable 2.5 m, 3 mm diameter. DEXIS describes Ti2 as the next sensor after Titanium |
| DEXIS Titanium | DEXIS says Titanium works with DTX Studio Suite. The Titanium page checked for this update did not list a pixel size | ||
| Schick 33 | 15 μm pixel. Theoretical resolution 33 lp/mm on the product page | Size 2 active area 25.6 × 36 mm. External 31.2 × 43 × 7.5 mm. Sizes 0 and 1 are also listed | USB 3 on the current page. Cable lengths 90, 180, and 270 cm |
| Xios XG Supreme | IFU dated August 2026: 15 µm pixel, theoretical resolution 33.3 lp/mm. CMOS-APS | Size 2 active area 25.6 × 36 mm. IFU external size 30.7 × 43.7 × 8.2 mm. The product page lists the same active area and a housing of 31.2 × 43 × 7.5 mm | USB 3.0. Cable up to 2.70 m. Sidexis 4.4 or higher with Intraoral Sensor Software 3.0 or higher, in that IFU |
| Carestream CS 6200, size 0 | 20 µm pitch. The size 0 manual lists a limited spatial resolution of 25 lp/mm and a typical resolution above 15 lp/mm | Active area 18.0 × 24.0 mm. 900 × 1200 pixels. Cable 3.0 m | USB 2.0. CMOS. These figures are from the size 0 user manual. Size 1 and size 2 are different sensors and are not filled from that manual |
| Vatech EzSensor HD | 14.8 µm. Theoretical resolution 33.78 lp/mm | Active area: size 1.0 is 20 × 30 mm, size 1.5 is 24 × 33 mm, size 2.0 is 26 × 36 mm. Thickness 4.8 mm. Cable 2.7 m | CMOS. Vatech rates the housing IP68 |
Holders and barriers from the old X-ray supplies list now belong with the imaging hub. The holder has to fit the thickness you just bought. The barrier has to be one the sensor maker clears.
Buying checklist
- Sizes. Size 2 for adult bitewings, size 1 for smaller mouths, size 0 for children. One size 2 for each room that takes radiographs at the same time.
- Software. Capture an image into the chart you already use. A sensor that opens a second library will not be used.
- The cable and the housing. Ask what the warranty covers and what a replacement size 2 costs in year three. Those are quote questions. They are not filled in above because they were not on the specification pages.
- Barrier and holder. Order them with the sensor. A barrier for a different body thickness changes the fit.
- Plate or sensor. Plates are the other digital path. Do not buy both unless you have a reason, such as plates for children and sensors for adults.
- Reprocessing. The CDC’s minimum, when a sensor cannot be heat sterilized or high-level disinfected, is an FDA-cleared barrier plus cleaning and an intermediate-level hospital disinfectant. Follow the sensor maker.
Related guides
Sensor questions
Do sensors replace a panoramic machine?
No. A sensor takes intraoral images. A panoramic unit takes the full-arch screening image. A CBCT takes volumes. You still need the sensor for bitewings even if you own the other two.
How many sensors does one office need?
One size 2 for each room that takes radiographs at the same time, plus a size 1 or 0 if you treat children. A single sensor for a four-chair office becomes the bottleneck, and it is also the only sensor you can drop.
Sources
Dentsply Sirona
Schick 33 sensors.
Dentsply Sirona
Xios XG Supreme instructions for use, August 2026.
Dentsply Sirona
Xios XG Supreme product page.
Dentsply Sirona
Discontinued intraoral sensors, including XIOS and XIOS Plus.
Dentsply Sirona support
Schick USB 2.0 interface supported through July 2027.
DEXIS
Ti2 sensor specifications.
DEXIS
Titanium sensor.
Carestream Dental
CS 6200 size 0 user manual.
Vatech
EzSensor HD.
Centers for Disease Control and Prevention
Sterilization and Disinfection. Dental Infection Prevention and Control.
Updated May 15, 2024cdc.gov (opens in a new tab)
What changed: Nov 2026: filled the Schick 33 and Xios XG Supreme rows from the current pages and the August 2026 instructions. The housing sizes on those two Xios sources do not match. No prices.
Related articles
Keep exploring related topics from Dental Country.

Intraoral Cameras: MouthWatch, DEXIS, Acteon Compared
Intraoral cameras compared on focus, capture, and software: MouthWatch, DEXIS, Acteon, Digital Doc, and Carestream.
Read article
Intraoral X-ray Units: Wall-Mount vs Handheld NOMAD
A wall-arm or handheld intraoral x-ray unit, a DC generator, and how Veraview, ProX, and NOMAD differ.
Read article
Panoramic X-ray Units: Planmeca, Vatech, Carestream
2D panoramic versus combo CBCT, ceph, and patient positioning, and how Planmeca, Dentsply Sirona, Vatech, Carestream, and DEXIS differ.
Read article
Phosphor Plate Systems: ScanX, VistaScan, Xios Scan
Phosphor plate systems: reusable plates, a reader that is not the x-ray head, and how ScanX, Xios, and Pspix differ.
Read article