Ultrasonic Scalers: Magnetostrictive vs Piezo
Magnetostrictive versus piezo ultrasonic scalers, and how Cavitron, Acteon, EMS, and NSK differ.
Reviewed by Dr. Sean Myran, DMDDoctor of Dental Medicine, University of Pennsylvania
How we rank explains how these product lists are ordered.
An ultrasonic scaler is the unit the hygienist uses at the chair. It is not the tank in the sterilization room, and it is not a hand sickle. The ultrasonic cleaner guide is the tank. The hand scaler guide is the sickle and the curette. This page is the powered scaler: magnetostrictive or piezoelectric, and the inserts that only fit one of those.
How to choose an ultrasonic scaler

- Magnetostrictive or piezo. A magnetostrictive insert is a metal stack that slides into the handpiece. A piezo tip screws on. Cavitron is the magnetostrictive unit most U.S. offices already own. Acteon, EMS, and NSK are piezo. The inserts do not cross between those two designs.
- The inserts are the purchase. A new generator with a new tip inventory is two costs. If the hygienists already have a drawer of Cavitron inserts, a piezo unit does not use them. If they want screw-on tips, a Cavitron will not take them.
- Water. Both designs need a waterline to the unit. A dry tip heats the tooth and burns the insert. The quote has to include the water connection, not only the box.
- Who holds it all day. Weight, the cord, and the foot control are the hygienist’s problem. Have that person use the handpiece before you sign. A unit the hygienist will not pick up is a hand-scaler practice with an expensive countertop.
- Air polishing is a different mode. Some magnetostrictive units add a powder jet. That is stain removal, not a substitute for the scaling insert, and the powder is its own supply.
How common scaler lines differ
Treat the table as product differences, not a score. The insert in the drawer decides which column you are in.

| Line | Type | Best fit | Watch for |
|---|---|---|---|
| Dentsply Cavitron | Magnetostrictive. Inserts slide in | Offices that already own Cavitron inserts and want the unit hygienists know | A 30K-style insert is still a Cavitron insert. It does not fit a piezo handpiece |
| Acteon Newtron | Piezoelectric. Tips screw on | Offices choosing a piezo unit and Acteon’s tip set | Tips are Acteon’s. A Cavitron stack will not thread onto this handpiece |
| EMS Piezon | Piezoelectric, with its own tip system | Offices that want the EMS tip library, including implant tips | Confirm the tip is cleared for the surface you are cleaning. An implant tip is not a heavy calculus tip |
| NSK Varios | Piezoelectric units sold through many U.S. dealers | Offices comparing a piezo unit with Acteon or EMS on weight and tip price | NSK tips are not EMS tips. The brand on the generator has to match the brand on the tip |
Dentsply Cavitron
Cavitron is the magnetostrictive scaler most U.S. hygiene rooms already use. The insert slides into the handpiece, and the insert series has to match that generator. Offices stay with Cavitron so the drawer of inserts still works. A Jet model adds air polishing. Buy the jet only if you will use the powder. Scaling still uses the insert, the water, and the power the hygienist sets.
Acteon
Newtron is Acteon’s piezoelectric scaler. The tip screws on, and the motion is the piezo pattern rather than the stack in a Cavitron insert. Compare it when the hygienist wants that handpiece, not when you are trying to keep using Cavitron inserts. The tip set is part of the quote. A unit with one tip in the box is not a working drawer.
EMS
Piezon is EMS’s piezoelectric line. Labs and perio offices look at it for the range of tips, including tips meant for implant surfaces. The tip has to be the one EMS clears for that surface. A heavy-calculus tip on an implant abutment is the wrong tip, even on the right generator. Water and power still come from the unit.
NSK
Varios is the NSK piezo unit dealers put next to Acteon and EMS. The comparison that matters is the handpiece the hygienist will hold and the price of the tips you will replace, not a brochure claim that one brand is quieter. NSK tips fit NSK. They are not a backup for an EMS handpiece that failed on a Friday.
Published specifications
Frequency and water specs below are from the manufacturer document named in the cell. A blank cell was not on that document. The insert or tip still has to match the generator. This table is not a score.
| Unit | Design | Frequency | Other stated spec |
|---|---|---|---|
| Dentsply Sirona Cavitron 300 series | Magnetostrictive. The insert slides into the handpiece | The maintenance instructions say to seat a sterilized 30 kHz Cavitron insert | The Steri-Mate handpiece is sterilized. The lavage control sets water flow at the tip. Lower flow is warmer water |
| Acteon Newtron | Piezoelectric. The tip screws on | 28–36 kHz in the Acteon/Satelec OEM brochure for Newtron modules | |
| EMS Piezon | Piezoelectric, with EMS tips | ||
| NSK Varios 970 | Piezoelectric | 28–32 kHz | Maximum output 11 W in G mode. Two 400 mL bottles. Unit weight 2.1 kg, excluding the attachment. Water pressure 0.1–0.5 MPa. NSK’s Varios 970 specifications |
A Cavitron insert does not thread onto a Newtron, Piezon, or Varios handpiece. NSK tips are not EMS tips. The handpieces and instruments hub is the category page for this scaler and for the hand instruments next to it.
Buying checklist
- The drawer you already own. If the inserts are Cavitron 30 kHz stacks, a piezo unit does not use them. If the hygienist wants screw-on tips, a Cavitron will not take them.
- The tips on the quote. A generator with one tip in the box is not a working drawer. Confirm the tip is the one the manufacturer clears for the surface, including implants.
- Water. Both designs need water at the tip. The Cavitron instructions tie flow to tip temperature. The Varios 970 manual states a supply pressure. A dry tip heats the tooth.
- Who holds it. Have the hygienist use the handpiece before you sign. Weight on a spec sheet is not the same as a full day.
- Air polishing. A powder jet on a magnetostrictive unit is stain removal. It is not a substitute for the scaling insert, and the powder is its own supply.
- The other ultrasonic. The tank in sterilization cleans instruments. It is not this machine. That buying guide is the ultrasonic cleaners guide.
Related guides
Scaler questions
Can Cavitron inserts go in a piezo scaler?
No. Magnetostrictive inserts slide into a Cavitron-style handpiece. Piezo tips screw onto a piezo handpiece. Buying the other generator means buying the other tips.
Is the sterilization-room ultrasonic the same machine?
No. That tank cleans instruments before they are sterilized. It does not scale teeth. The chairside unit is this page.
Sources
Dentsply Sirona
Cavitron 300 Series maintenance guide.
Acteon / Satelec
OEM brochure, Newtron ultrasonic frequency.
NSK
Varios series specifications.
NSK
Varios 970 operation manual.
Related articles
Keep exploring related topics from Dental Country.

Dental Handpieces: High vs Low Speed, Synea, S-Max
Air versus electric and high-speed versus low-speed handpieces, and how W&H, NSK, Morita, and Midwest differ.
Read article
Capsule Mixers and Amalgamators: Silamat, RotoMix, CM-II
Silamat S6, RotoMix, Ultramat 2, and GC CM-II capsule mixers, plus the cover and fork that fail first.
Read article
Apex Locators: Root ZX II, Propex Pixi, CanalPro
A standalone apex locator or one built into the endo motor, and how Root ZX, Propex, Apex ID, and CanalPro differ.
Read article
Dental Carvers: Hollenback, Ward, Tufts and Discoid
Ward, Hollenback, discoid-cleoid, and IPC carvers, plus the PFI and Bliss instruments that place composite.
Read article